Alpha Technologies FXM2000 Specifications

Browse online or download Specifications for Uninterruptible power supplies (UPSs) Alpha Technologies FXM2000. Alpha Technologies FXM2000 Specifications User Manual

  • Download
  • Add to my manuals
  • Print
  • Page
    / 88
  • Table of contents
  • TROUBLESHOOTING
  • BOOKMARKS
  • Rated. / 5. Based on customer reviews
Page view 0
Your Power Solutions Partner
member of The Group
Alpha FXM 650, 1100, 2000 UPS
Installation and Operation Manual
Page view 0
1 2 3 4 5 6 ... 87 88

Summary of Contents

Page 1 - Alpha FXM 650, 1100, 2000 UPS

Your Power Solutions Partnermember of The Group™Alpha FXM 650, 1100, 2000 UPSInstallation and Operation Manual

Page 2

017-230-B0 Rev 08108        Battery Bre akerThis circuit breaker provides over-current protection and is uses as an on/off switch for the battery

Page 3

9017-230-B0 Rev 0810C1: The C1 contact is energized when line power is unqualified and the Alpha FXM provides backup battery power to the load(s).

Page 4 - Table of Contents

017-230-B0 Rev 081010ATS (C8): When the Alpha FXM is in the Inverter mode, this normally open relay closes (Figure 6), sending 48 VDC (FXM 650-48,

Page 5

11017-230-B0 Rev 08103.  Site PlanningWARNING!Restricted Access: The Alpha FXM must be installed in a restricted area accessible only by qualied

Page 6 - 1.  Safety

017-230-B0 Rev 081012• In the Generator mode, the Alpha FXM’s range of acceptable input frequency and voltage is expanded to accept the fluctuatio

Page 7

13017-230-B0 Rev 08104.  Unpacking Alpha FXMFollow these guidelines for unpacking the Alpha FXM.WARNING!The Alpha FXM. is heavy, up to 16 kg (35 l

Page 8

017-230-B0 Rev 0810145.  InstallationWARNING!The Alpha FXM module MUST be correctly grounded for proper operation.The input and output lines to an

Page 9 - 2.  General Description

15017-230-B0 Rev 08105.1.1  Mounting the Alpha FXMThe Alpha FXM can be placed on a shelf with no other parts needed. Any version of the FXM can be

Page 10

017-230-B0 Rev 0810165.2  Wiring the External BatteriesWARNING!The batteries must be installed by qualied personnel trained in the safe use of hi

Page 11 - Microprocessor

17017-230-B0 Rev 0810CAUTION!Torque the battery terminals according to the manufacturer’s specications as given on the name plate or data sheet.2

Page 13 - 3.  Site Planning

017-230-B0 Rev 0810185.2.2  Wiring the Alpha FXMWARNING!Make sure the line power is off. Switch off all input and output circuit breakers on the A

Page 14

19017-230-B0 Rev 08106.   OperationThe following subsections describe the operation of the Alpha FXM:• Communicating with the Alpha FXM.• Operat

Page 15 - 4.  Unpacking Alpha FXM

017-230-B0 Rev 0810206.1  Communicating with the Alpha FXMThere are several ways you can communicate with the Alpha FXM UPS:1. Using the control

Page 16 - 5.  Installation

21017-230-B0 Rev 08106.2  Operating the Control PanelThe LCD control panel provides “at a glance” monitoring. This panel, when used along with the

Page 17

017-230-B0 Rev 081022Table C — UPS Operating ModesLCD display DescriptionSHUTDOWN The Alpha FXM’s inverter is switched off. Line power is discon

Page 18 - 5.2.1  Procedure

23017-230-B0 Rev 0810The CONTROL MENU (Table D) lets you control, program and adjust the Alpha FXM for connection to traffic intersection equipment

Page 19 - CAUTION!

017-230-B0 Rev 0810246.3  Switching the Alpha FXM On and OffUnder normal operation, the Alpha FXM is always powered ON to supply uninterruptible p

Page 20 - 5.3  UATS and (UGTS) Option

25017-230-B0 Rev 08106.4  Operating the Alpha FXMThe control menu (Table D) lets you operate the Alpha FXM or program it to suit your operating co

Page 21 - 6.   Operation

017-230-B0 Rev 081026Table D — Control MenuLCD display Meaning DescriptionQUAL TIME Line qualify timeLets you set how long it takes for the Alph

Page 22 - Option 2

27017-230-B0 Rev 08106.5  Making MeasurementsThe System Status menu lets you make measurements of various Alpha FXM inputs, outputs, temperatures

Page 23 - 120/60/N

Alpha FXM 650, 1100, 2000 UPSInstallation and Operation ManualFor technical support, contact Alpha Technologies:Canada and USA: 1-888-462-7487Internat

Page 24 - LCD display Description

017-230-B0 Rev 0810286.6  Viewing the 100-Event LogUsing the LCD display, RS-232 or web interface, you can view up to the last 100 events the Alph

Page 25 -  Starting at the Logo

29017-230-B0 Rev 08106.7  Communicating with the RS-232 interfaceThe following subsections describe the operation of the Alpha FXM via the RS-232

Page 26

017-230-B0 Rev 0810306.7.1  Wiring the RS-232 portThe Alpha FXM’s front panel has a DE-9 female connector. When connected to a PC with Windows Hyp

Page 27 - 6.4  Operating the Alpha FXM

31017-230-B0 Rev 08106.8  Using the Main MenuThe Alpha FXM’s main menu screen runs on a command line system. This program does not recognize the b

Page 28 - Table D — Control Menu

017-230-B0 Rev 0810326.9  RS-232 Menu TreeSubmenus #1, 2 and 4 are read-only screens for monitoring the Alpha FXM. To control the Alpha FXM, use s

Page 29 - 6.5  Making Measurements

33017-230-B0 Rev 0810Table G — Line StatusNormalThe line is within specifications. See specifications, “Boost/Buck/Line Transfer Thresholds”. The

Page 30 - Over Load

017-230-B0 Rev 0810346.9.3  Fault and Alarm DisplaysFault and alarm displays any malfunctions the Alpha FXM has encountered. Also see "Troubl

Page 31

35017-230-B0 Rev 08106.9.4  Adjusting and Controlling the Alpha FXMThe Maintenance submenu lets you control the Alpha FXM and change selected item

Page 32 - Procedure

017-230-B0 Rev 0810366.9.5  Programming the Dry Contacts and the ClockThe Alpha FXM’s front panel contacts (C1 to C6) can be programmed to meet yo

Page 33 - 6.8  Using the Main Menu

37017-230-B0 Rev 08106.9.6  Setting the Timer ContactThe front panel’s timer contact can be programmed to suit your application. See "Contact

Page 34 - 6.9  RS-232 Menu Tree

017-230-B0 Rev 08102Table of Contents1. Safety ...

Page 35 - 6.9.2  Output Status

017-230-B0 Rev 0810386.9.7  Setting the Date and TimeTable N — Setting the Date and TimeEnter command UPS display Descriptionclock and press Ent

Page 36 - Table J — Alarms

39017-230-B0 Rev 08106.9.8  Viewing the Serial NumberTo display the serial number of the Alpha FXM UPS, type "∗QY0" at the command line

Page 37

017-230-B0 Rev 0810406.9.10  100-Event LogUp to 100 events are stored in the Alpha FXM’s log. If more than 100 events occur, the oldest is over-wr

Page 38 - Programming the Dry Contacts

41017-230-B0 Rev 08106.9.11  Communicating with the Alpha UPS MonitorIntroductionThe Alpha UPS Monitor graphical user interface (GUI) provides web

Page 39

017-230-B0 Rev 0810426.9.12  Checking Your Windows Computer for the .NET Framework1. Click on the Start button.2. Go to and click on Settings.3.

Page 40

43017-230-B0 Rev 08106.9.13  Installation and Set UpThe following tools and materials are required:• Alpha UPS Monitor, available for download fr

Page 41

017-230-B0 Rev 0810446.10  OperationThe various screens are described on the following pages and operate like Web or Windows-type screens. Point a

Page 42 - 6.9.10  100-Event Log

45017-230-B0 Rev 08106.10.2  UPS MonitoringThese read-only screens show the Alpha FXM’s current input and output values and other measurements.Inp

Page 43 - Introduction

017-230-B0 Rev 081046Relay & Load ShedShows how the front panel dry contacts are configured. If any relays are used for load shedding, the time

Page 44

47017-230-B0 Rev 08106.10.3  UPS MaintenanceThe UPS Maintenance screens are used to configure and adjust the Alpha FXM to meet your operating needs

Page 45

3017-230-B0 Rev 08107. Maintenance ...

Page 46 - 6.10  Operation

017-230-B0 Rev 081048Figure 24 — UPS Maintenance: Inverter screenAn accurate battery runtime estimation requires the following parameter to be a

Page 47 - Battery & Inverter

49017-230-B0 Rev 0810Figure 25 — UPS Maintenance: Relay & Load Shed screenControlling the external fan by temperature triggered dry contactT

Page 48 - User Input Status

017-230-B0 Rev 081050Dry contact functions are not programmable through the LCD. Use the RS-232 GUI or the HyperTerminal instead.2. RS-232 GUI –

Page 49 - Unit Configuration

51017-230-B0 Rev 08103. RS-232 HyperTerminal – the Temperature trigger function can be assigned to any available dry contacts as described in &qu

Page 50 - Inverter

017-230-B0 Rev 081052A typical application of this timer controlled dry contact function is to control a traffic light. When the grid power fails,

Page 51

53017-230-B0 Rev 0810Figure 31 — Time Of Day Action StatusOnce the Time of Day Action is configured, the Alpha FXM will automatically disable the

Page 52

017-230-B0 Rev 081054PasswordIs used to set the Alpha FXM’s password. The factory set password is 1111.Figure 33 — UPS Maintenance: Password scr

Page 53

55017-230-B0 Rev 0810Figure 35 — User Input Configuration: Setting the Trigger TypeFigure 36 — User Input Configuration: Setting the Logic Lev

Page 54

017-230-B0 Rev 081056Figure 38 — User Input Current StatusFigure 39 — User Input Current StatusPerform a quick test by shorting the User Input

Page 55 - Time & Date

57017-230-B0 Rev 0810OperationMany of the screens used for Ethernet communications look and function the same and contain the same infor-mation as

Page 56 - User Input

017-230-B0 Rev 081041.  SafetySAVE THESE INSTRUCTIONS: This manual contains important safety instructions that must be followed during the install

Page 57

017-230-B0 Rev 081058The default command can be issued via the RS-232 HyperTerminal or the RS-232 GUI as follows:• RS-232 HyperTerminal – type de

Page 58

59017-230-B0 Rev 0810Table P — List of ParametersMaximum battery charging currentTemperature compensation of battery charging Maximum allowable

Page 59 - Operation

017-230-B0 Rev 081060Event HistoryThis screen shows the last 100 events recorded by the Alpha FXM. Choosing a number in the Event Index drop-down

Page 60

61017-230-B0 Rev 0810To view all the events, click on the View All button to open the Event Log Monitor window. Clicking on the Clear History butt

Page 61

017-230-B0 Rev 081062Upgrade FilesThis feature is available only on Alpha FXM UPS equipped with the network interface card factory option.To upgra

Page 62 - Alarms & Faults

63017-230-B0 Rev 0810Keep AliveThe Keep Alive feature can be used to reset power when a communication failure is detected. The purpose of the rese

Page 63

017-230-B0 Rev 081064Keep Alive st atus/manual control:a. The Status field allows the user to enable or disable the Keep Alive function. When disa

Page 64 - Communications

65017-230-B0 Rev 0810CAUTION!To successfully complete this procedure, you should have a working knowledge of network protocols and how to congure

Page 65 - Keep Alive

017-230-B0 Rev 0810666.11.3  Types of TriggerThere are 3 types of trigger:Edge triggerWhen the user input changes from one state to the other, the

Page 66

67017-230-B0 Rev 0810Level Altern ativeWhen the level is set to High, the Alpha FXM is triggered to perform the next action when the user input ch

Page 67

5017-230-B0 Rev 08101.2  General Warnings and CautionsYou must read and understand the following warnings before installing the Alpha FXM and its

Page 68 - 6.11.3  Types of Trigger

017-230-B0 Rev 0810687.  Maintenance7.1  Updating the SoftwareThe Alpha FXM’s firmware can be reinstalled or updated to the latest version with thi

Page 69 - Action #2 Action #1

69017-230-B0 Rev 08101: Type fbulk.2: Erase pop-up appears.6. In the uBug12 screen, type (all lower case) fbulk and press ENT ER. The erase pop-u

Page 70 - 2: Screen shows “Connected”

017-230-B0 Rev 0810708. When the software has finished loading into the Alpha FXM, the pop-up shows “Loaded OK in (xx) sec onds.” If an error mess

Page 71

71017-230-B0 Rev 08107.2  Testing and Replacing the Batteries7.2.1  Battery lifeBatteries lose their ability to store power as they age. Regularly

Page 72 - Firmware is loaded

017-230-B0 Rev 0810727.2.3  Battery MaintenanceThe batteries supplied with this unit are sealed and maintenance free. Regularly ensure that all co

Page 73 - 7.2.2  Battery Run Time

73017-230-B0 Rev 0810WARNING!Read and understand the battery safety instructions in “Product Safety Information”.CAUTION!Make sure all the replace

Page 74 - Tools and Materials Required

017-230-B0 Rev 0810747.3  Preventative MaintenancePerform preventative maintenance on the Alpha FXM module every 6 to 12 months. For mission criti

Page 75

75017-230-B0 Rev 08108.  TroubleshootingWhen the front panel alarm LED is illuminated or flashing, the Alpha FXM has a malfunction. The alarm and f

Page 76 - 7.3  Preventative Maintenance

017-230-B0 Rev 081076Table S — Fault SubmenuLCD Shows Problem Description What To DoOverload FaultThe load draws more power than the Alpha FXM

Page 77 - 8.  Troubleshooting

77017-230-B0 Rev 08109.  SpecificationsTable U — Mechanical SpecicationsParameter ValueDimen sion s H x W x D mm (in) FXM 1100-2000: 5.22 x 15.

Page 78 - Table S — Fault Submenu

017-230-B0 Rev 08106• Never let live battery wires touch the Alpha FXM, the enclosure or any other metal objects. This can cause a fire or explosi

Page 79 - 9.  Specifications

017-230-B0 Rev 081078Table V — Electrical SpecicationsParameter ValueInputVoltage (nominal), VAC120 or 230, optional 220, optional 210 for FXM

Page 80 - Parameter Value

79017-230-B0 Rev 0810Table V — Electrical SpecicationsParameter ValueBattery Char ger Current, AmpsFXM 650-48/1100/2000: 48 VDC.Battery Charger

Page 81 - Table X — Regulatory

017-230-B0 Rev 08108010.  Puekert Number and Bat tery Capacity10.1  IntroductionThe Alpha FXM series UPS units run on batteries when the AC utilit

Page 82 - 10.1  Introduction

81017-230-B0 Rev 081010.4  ExampleThe following example shows how to calculate Peukert’s number and capacity from a configured battery string.Consi

Page 83 - 10.4  Example

017-230-B0 Rev 08108210.5  Using the SpreadsheetDownload the spreadsheet “Peukert’s Parameters Calculator.xls” from www.alpha.ca website. Enter th

Page 84 - 10.5  Using the Spreadsheet

83017-230-B0 Rev 081011.  WarrantyAlpha Technologies Ltd. warrants all equipment manufactured by it to be free from defects in parts and labor, fo

Page 85 - 11.  Warranty

017-230-B0 Rev 081084Complete the following for your records:Serial # Options Purchase Date This unit w

Page 87

Visit us at www.alpha.ca Due to continuing product development, Alpha Technologies reserves the right to change specifications without notice. Copyrigh

Page 88 - Visit us at www.alpha.ca

7017-230-B0 Rev 08102.  General Description2.1  OverviewThe Alpha FXM is available in 3 models – FXM 650, FXM 1100 and FXM 2000. The FXM 650 and t

Comments to this Manuals

No comments